a5229103f687f873fd55653d98a079ae4e91ec2f
Two more metrics on the same chart, from the portal's new energy_wh and co2e_g daily columns. - Energy in watt-hours, carbon in grams CO2e, both for the day shown. - Continuous metrics use the 1/2/5 axis rule (not the integer rule reserved for counts), so energy ticks read 500 Wh rather than being rounded to whole people-style numbers. - Labels carry units, so a reader never has to guess what the axis measures. - Same measured-vs-estimated provenance as the data layer: GreenPT models use facts fitted from their own impact API, everyone else a labelled proxy. The docs page on estimation is still to be written; the factor table and its sources are in metrics_snapshot.py. Harness extended: one bar per measured day for each, no NaN in markup, and axis labels matching ^[\d,]+(\.\d+)? (Wh|g)$ so a unit prefix or a forced integer axis fails the build.
Languages
Python
99.5%
Dockerfile
0.5%